Prime Fleet Dielectric Services, LLC
Prime Fleet Dielectric Services, LLC
More

Dielectric Testing and Inspections for Companies on the Go

Dielectric Testing and Inspections for Companies on the GoDielectric Testing and Inspections for Companies on the GoDielectric Testing and Inspections for Companies on the Go

Keeping "Essentials" Safe and Fleets Compliant


Contact Us

5672451185

Dielectric Testing and Inspections for Companies on the Go

Dielectric Testing and Inspections for Companies on the GoDielectric Testing and Inspections for Companies on the GoDielectric Testing and Inspections for Companies on the Go

Keeping "Essentials" Safe and Fleets Compliant


Contact Us

5672451185

About

On-Site Services

Dielectric Testing and Boom Inspections per ANSI A92.2, A10-31 (Servicing  East of the Mississippi, based on fleet volume)

Some highlights of our Dielectric services:

-  The insulators on bucket trucks are waxed as per the manufacturer to inhibit any premature breakdown of the fiberglass and to remove any debris such as oil, grease and tar that may allow electricity to move across the insulator.

- The outriggers are sprayed with a dry moly and the boom and chains are fully lubricated. 

- All access panels on the boom are removed to gain proper access to the interior of the boom to inspect all the fasteners, lift rods, chains and hydraulic hoses. 

- When inspecting digger derricks, we fully extend the winch rope to inspect for fraying and when possible, we      remove the rope from the derrick to insure for a proper dielectric test reading as per ANSI A10.31 Section 5.2.1

- All hot sticks are cleaned, dry tested per the manufacturer, waxed and wet tested per OSHA ASTM F711

- Prior to testing blankets and line hoses, each one is inspected to verify no cuts or abrasions are present that would inhibit its insulating value .

- Ground sets and mechanical jumpers are tested for their resistance. Prior to testing they are visually and physically inspected to identify any cuts or nicks in the insulation.

Our pricing is simple and straight forward. There are no travel, set up or shop fees added.

Medium duty bucket truck 

Dielectric testing of the upper boom insulator, chassis insulator and the bucket liner per ANSI A92.2

Full inspection of boom, chassis and cab per ANSI A92.2

Cost with liner: $475.00 Cost without liner: $375.00 Add DOT inspection: $75.00

Light duty bucket truck or tracked machine

Dielectric testing of the upper boom insulator, chassis insulator and the bucket liner per ANSI A92.2

Full inspection of boom, chassis and cab per ANSI A92.2

Cost with liner: $425.00 Cost without liner: $325.00 Add DOT inspection: $50.00

Digger derrick truck or tracked machine

Dielectric testing of the third out insulator per ANSI A10.31

Full inspection of the derrick, chassis and cab per ANSI A10.31

Cost: $325.00 Add DOT inspection: $75.00

Hot Sticks

Tested per ASTM F711

Shotgun style: $15.00

Standard Tel-O (Up to 20’): $30.00

Extended Tel-O: $60.00

36”X36” Blankets (full and split)

Tested per ASTM D1048

Cost: $15.00

Line Hoses (4’ & 6’)

Tested per ASTM F478, ASTM D1050 and ASTM F1236

Cost: $10.00

Ground sets & Mechanical jumpers (resistance ONLY)

Tested per ASTM F855

Cost: $25.00

Keeping your Equipment on the Road!

Contact Us

Get a Fleet Quote Today!

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Need PM Services for your Fleet?

#dielectrictesting

OUR PARTNER

Mobile oil changes and preventative maintenance for companies on the go.

Copyright © 2021 Prime Fleet Dielectric Services, LLC - All Rights Reserved.

  • Privacy Policy

Powered by GoDaddy

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.